PUMP & MACERATOR SERVICES

Macterators – Saniflo & Grunthos

Drain & Pipe Problems We Can Assist With


Saniflo Pipe Clearance & Saniflo Box Servicing.

Macerator faults & breakdowns are caused by a number of issues.

Pump box failure is generally caused by a lack of maintenance.

This causes the pump boxes and pipework to eventually fail.

Scale builds up within the pump boxes, this can prevent the diaphrams, valves and float switches from working, which can cause the box to run continuously or just cut out.

Scale can also buildup on the side walls of the pipework.

Pipe sizes range from 22mm to 32mm

Anything other than the three P’s should not enter the system.

Wipes shouldnt be used on a conventional toilet system, one chopped wipe in a macerator system can be very tricky to retrieve.

Foriegn items entering the system can cause the blade to jam or to send chopped particals into the pipe system, these particals can get caught on bends & rough joins etc.

Saniflo pipework should be installed with 45 degree bends and as little as possible.

22mm 90 degree bends shouldnt be used as they cause a stoppage point.

Clearing scale from the side walls of 22mm & 32mm pipework can be very time consuming and not always achievable depending on the number, type of bends used, distance and location of pipework.

Systems are generally installed in areas where conventional waste plumbing cant be used, basements, loft spaces etc. The pipework can be found – under floorboards, in walls, voids & loftspaces

Quite often it is cost effective to re route or replace the pipework with new, but sometimes this is not achievable.

Descaling fluid should be used regularly both for the pump box and pipework.

The pipework should isolated and filled with the fluid to allow to cleanining fluid to break down the scale, again quite often this is not achievable.

It is common to find a system that has been installed for years that “has been working fine untill now”, scale can take years to build up, gradually reducing the circumfrance of the inside wall of the pipework.


Baths, Sinks, Showers, Basins, Toilets, Urinals.

Macerators – Saniflo Servicing, Saniflo Clearance Grunthos servicing & Clearance.


Manholes, Inspection Chambers,

Interceptors – Windsor Trap, Buchan Trap.

Floor Drains, Roof Drains.

Stack Pipes, Soil Vent Pipes, Flood Valves.


Accos drains, Slotted Kerbs, French Drains,

Silt Traps & Soakaways,

Gutter Cleaning & Repairs.


Commercial Drains:-

Kitchens, Fridge & Chiller Cabinets, Washing Machines, Dish Washers, Coffee Machines, Fat Traps etc.


Industrial Drains:-

Shute Cleaning, Trough Cleaning, Duct Cleaning, Pipework Cleaning, Specialist cleaning Etc.


To Clear Build-Up’s Of :-

Roots, Scale, Debris, Rubble , Silt , Foreign Objects, Wipes, Fats, Oils, Grease, Fridge Jelly, Cabinet Slime Etc.

Steel & Cast Iron, Copper, Brass, PVC, Clay & Pitch Fibre.


Additional Services :-

Stuck Drain Rod Removal

Pipe Alterations & Pipe Repairs

PPM- Regular Maintenance Plans

Manhole Cover Repairs

Burried Manhole locating

Drain Smells

Drain tracing


Minor Plumbing:-

Cistern Flush Valve & Toilet Fill Valve Repair & Replacement, Leaking Toilets, Toilet Replacement


Contact Our Team For A Quote.

Kent , Outer London Bouroughs, South Essex, Surrey & East Sussex

Drain Industrys We Cover

Need a blocked drain clearing?

We can assist with domestic & residential drain blockages.

Commercial drain clearance.

Blocked building site drains.

univeristy, college, school drain clearing,

Hotel drain problems

Drain blockages in Pubs & Clubs.

Factory pipe clearance and industrial drain unblocking.

Plant & Machinery pipe cleaning.

Blockages in marine & ship drains & pipes.


For more info on our drain clearance & maintnance services follow the link below.

Phone

07873 818841

Jetawaycleansing@gmail.com

HEAD OFFICE

57A Rochester Crescent,

Hoo, Rochester, Kent, ME3 9JH

OUR AREAS

KENT

LONDON BOROUGHS (OUTER)

SOUTH ESSEX

SURREY

EAST SUSSEX